An RO flow restrictor, also called a drain valve, is the small inline part on the drain line of an RO plant. It holds back the reject water so pressure builds on the membrane, and lets just enough through to carry the rejected salts away. Axtron Pakistan supplies 300cc, 450cc, 650cc, 800cc and 1200cc flow restrictors for domestic and semi commercial RO plants. Use the size chart below to match one to your membrane, and see the current price on each product card.
What a Flow Restrictor Does in an RO System
An RO membrane splits the incoming water into two streams: pure water, and reject water that carries the salts away to the drain. The flow restrictor sits on that drain line.
- It builds pressure. By holding back the drain flow, it keeps pressure on the membrane, so water is pushed through it and pure water is produced.
- It keeps the membrane flushed. It still lets a set amount of water run to drain, which washes the rejected salts off the membrane surface.
The cc number is the drain flow it allows, in millilitres per minute. A 300cc restrictor lets about 300 ml a minute run to the drain. Without a flow restrictor, most of the water simply runs to the drain and the plant makes little pure water.
Flow Restrictor Size Chart by Membrane GPD
These are the default pairings our technicians use:
| Membrane capacity | Flow restrictor |
|---|---|
| 100 GPD | 300cc |
| 100 GPD, high-TDS water | 450cc |
| 200 GPD | 650cc |
| 400 GPD | 800cc |
| 800 GPD | 1200cc |
Where the water TDS is high, our technicians sometimes fit a larger size than the default, as with 450cc on a 100 GPD membrane. On plants with more than one membrane, or very high TDS, they sometimes fit two flow restrictors, after checking what works best on that plant. More water to drain carries away more of the salts. So if you are not sure, send us your membrane size and your water’s TDS, and we will tell you which one to use.
GPD is gallons per day, the rated capacity printed on the membrane. See our domestic membranes for 100 GPD and our semi commercial membranes for 200 GPD and above. This range covers domestic and semi commercial plants. For commercial plants with 4040 or 8040 membranes, talk to us.
Signs of a Wrong or Blocked Flow Restrictor
- Too small or blocked: very little water comes out of the drain. The membrane is not flushed properly, so it scales sooner and the TDS of your drinking water slowly rises.
- Too large: a lot of water runs to the drain, pressure on the membrane stays low, and the plant makes less pure water.
If you notice either, check the restrictor before replacing the membrane. A TDS meter helps you see when output TDS starts rising.
Upgrading the Membrane? Change the Flow Restrictor Too
The flow restrictor is matched to the membrane. If you move from a 100 GPD to a 200 GPD membrane, change the restrictor as well (from 300cc to 650cc). Otherwise the new membrane will not give its full output.
Flow Restrictor Price in Pakistan – What Decides It
The flow restrictor price in Pakistan depends mainly on the size: larger cc restrictors for bigger membranes cost more than the 300cc. The current price of every size is shown on its product card. For tube connectors and other small parts, see domestic RO fittings.
Buy Flow Restrictors in Multan, Lahore, Bahawalpur and Across Pakistan
- Multan (Head Office): Akbar Road, Tipu Sultan Colony, Multan. 0302-1635555 · 0300-4773040 · 061-4544442
- Lahore: 91-A Feroz Pur Road, Lahore. 0304-8205829 · 042-37502222
- Bahawalpur: Opposite Sadiq Public School, Ahmad Pur East Road, Bahawalpur. 0302-7401250 · 062-2201005
All three shops are open Saturday to Thursday, 9 AM to 7 PM, and closed on Friday. Bring a water sample and we test TDS, pH, hardness and arsenic.
In Multan, Lahore and Bahawalpur our technicians fit flow restrictors and service RO plants, including plants bought elsewhere. For commercial plants in other cities, our commercial RO plant technicians visit for consultation and service, with support by phone and video call.
Rest of Pakistan: we confirm your order on WhatsApp or phone and deliver by courier in 2–5 working days. Cash on delivery is available: delivery is free on orders of Rs. 2,000 and above, and smaller orders have a delivery charge. On orders above Rs. 20,000, half is paid in advance by bank transfer and the rest on delivery. In other cities we can connect you on WhatsApp with an independent local technician who charges you directly; they are not Axtron staff.
See also domestic RO plants, semi commercial RO plants, all RO membranes and all RO plant parts. You can also read about our service on the water filter in Multan and RO plant in Lahore pages.
Frequently Asked Questions
What does a flow restrictor do in an RO system?
It sits on the drain line and holds back the reject water, so pressure builds on the membrane and pure water is produced. It still lets enough water to drain to flush the rejected salts off the membrane.
Which flow restrictor do I need for a 100 GPD membrane?
300cc is the default. Where the water TDS is high, our technicians often use 450cc.
What does 300cc or 800cc mean?
It is the drain flow the restrictor allows, in millilitres per minute. A bigger membrane needs a bigger cc restrictor.
My plant has two membranes. Which restrictor do I use?
Plants with more than one membrane, or with high-TDS water, sometimes use two flow restrictors. Our technicians check what fits best on your plant, so send us the number and size of your membranes and your water’s TDS.
Can an RO plant work without a flow restrictor?
No. Without one, most of the water runs straight to the drain, pressure on the membrane stays low and the plant makes little pure water.
Do I need a new flow restrictor when I change the membrane?
If the new membrane is the same size, the restrictor can stay unless it is blocked. If you change to a bigger GPD membrane, change the restrictor to match.
Do you deliver flow restrictors to Karachi and Islamabad?
Yes. We deliver across Pakistan by courier in 2–5 working days. Tell us your membrane size first, so we can confirm the right restrictor.